For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
3-year product warranty on Fluke-116 DMM, 2-year warranty on Fluke-62 IR Thermometer and 1-year warranty on accessories
What's Included:
    - Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 62 Infrared Thermometer
- Fluke TL75 Hard Point Test Lead Set      
- Fluke TPak ToolPak Magnetic Meter Hanging Strap      
- NEW! Fluke C115 Deluxe carrying case with shoulder strap      
- Fluke 80BK Integrated Temperature Probe      
- Fluke 80AK Thermocouple Adapter
- NEW! Fluke 80PK-11 Pipe Wrap Thermocouple
Features
    - Built in thermometer for HVAC applications
- Microamps to test flame sensors
- LoZ: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
    
        
            | Specifications | 
        
            | Maximum voltage between any terminal and earth ground |  | 
        
            | Surge protection | 
                
                    
                        |  | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |  | 
        
            | Display | 
                
                    
                        | Digital: | 6,000 counts, updates 4 per second |  | 
        
            | Bar graph | 
                
                    
                        |  | 33 segments, updates 32 per second |  | 
        
            | Operating Temperature |  | 
        
            | Storage Temperature |  | 
        
            | Battery type | 
                
                    
                        |  | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |  | 
        
            | Battery Life | 
                
                    
                        |  | 400 hours typical, without backlight |  | 
    
    
        
            | Accuracy Specifications | 
        
            | DC millivolts | 
                
                    
                        | Range: | 600.0 mV |  
                        | Resolution: | 0.1 mV |  
                        | Accuracy: | ± ([% of reading] + [counts]): 2.0% + 3 |  | 
        
            | DC volts | 
                
                    
                        | Range/Resolution: | 6.000 V / 0.001 V |  
                        | Range/Resolution: | 60.00 V / 0.01 V |  
                        | Range/Resolution: | 600.00 V / 0.1 V |  | 
        
            | Auto volts | 
                
                    
                        | Range: | 600.0 V |  
                        | Resolution: | 0.1 V |  
                        | Accuracy: | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz)
 |  | 
        
            | AC millivolts1 true-rms | 
                
                    
                        | Range: | 600.0 mV |  
                        | Resolution: | 0.1 mV |  
                        | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
 |  | 
        
            | AC volts1 true-rms | 
                
                    
                        | Range/Resolution: | 6.000 V / 0.001 V |  
                        | Range/Resolution: | 60.00 V / 0.01 V |  
                        | Range/Resolution: | 600.0 V / 0.1 V |  
                        | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
 |  | 
        
            | Continuity | 
                
                    
                        | Range: | 600 §Ù |  
                        | Resolution: | 1 §Ù |  
                        | Accuracy: | Beeper on < 20 §Ù, off > 250 §Ù; detects opens or shorts of 500 μs or longer. |  | 
        
            | Ohms | 
                
                    
                        | Range/Resolution: | 600.0 §Ù / 0.1 §Ù |  
                        | Range/Resolution: | 6.000 k§Ù / 0.001 k§Ù |  
                        | Range/Resolution: | 60.00 k§Ù / 0.01 k§Ù |  
                        | Range/Resolution: | 600.0 k§Ù / 0.1 k§Ù |  
                        | Range/Resolution: | 6.000 M§Ù / 0.001 M§Ù |  
                        | Accuracy: | 0.9 % + 1 |  
                        | Range/Resolution: | 40.00 M§Ù / 0.01 M§Ù |  
                        | Accuracy: | 1.5 % + 2 |  | 
        
            | Diode Test | 
                
                    
                        | Range/Resolution: | 2.000 V / 0.001 V |  
                        | Accuracy: | 0.9% + 2 |  | 
        
            | Capacitance | 
                
                    
                        | Range/Resolution: | 1000 nF / 1 nF |  
                        | Range/Resolution: | 10.00 μF / 0.01 μF |  
                        | Range/Resolution: | 100.0 μF / 0.1 μF |  
                        | Range/Resolution: | 9999 μF / 1 μF |  
                        | Range/Resolution: | 100 μF to 1000 μF |  
                        | Accuracy: | 1.9% + 2 |  
                        | Range/Resolution: | > 1000 μF |  
                        | Accuracy: | 5% + 20% |  | 
        
            | LoZ capacitance | 
                
                    
                        | Range: | 1 nF to 500 μF |  
                        | Accuracy: | 10% + 2 typical |  | 
        
            | Temperature2 (Type-K thermocouple) | 
                
                    
                        | Range/Resolution: | -40 °C to 400 °C / 0.1 °C |  
                        | Accuracy: | 1% + 102 |  
                        | Range/Resolution: | -40 °F to 752 °C / 0.2 °F |  
                        | Accuracy: | 1% + 182 |  | 
        
            | AC μamps true-rms (45 Hz to 500 Hz) | 
                
                    
                        | Range/Resolution: | 600.0 μA / 0.1 μA |  
                        | Accuracy: | 1.0% + 2 |  | 
        
            | DC μamps | 
                
                    
                        | Range/Resolution: | 600.0 μA / 0.1 μA |  
                        | Accuracy: | 1.0% + 2 |  | 
        
            | Hz (V or A input)2 | 
                
                    
                        | Range/Resolution: | 99.99 Hz / 0.01 Hz |  
                        | Range/Resolution: | 999.99 Hz / 0.1 Hz |  
                        | Range/Resolution: | 9.999 Hz / 0.001 Hz |  
                        | Range/Resolution: | 50.00 Hz / 0.01 Hz |  
                        | Accuracy: | 0.1% + 2 |  | 
    
 
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. 
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. 
    
        
            | Mechanical & General Specifications | 
        
            | Size | 
                
                    
                        | Height: | 27.62 cm (10.875") |  
                        | Length: | 15.875 cm (6.25") |  
                        | Width: | 5.6 cm (2.203") |  | 
        
            | Weight |  | 
        
            | Warranty |  |