TPI 390 TDS/Salt Meter

Measure Total Dissolved Solids (TDS), salt and temperature for food, water quality and HVAC maintenance. Easy-to-read LCD display. Measures temperature, TDS concentration and salt levels in solutions.

Product Features

  • Measure total dissolved solids (TDS), salt and temperature for food, water quality and HVAC maintenance
  • Easy-to-read LCD display
  • LR44 or LR1154 button battery
  • Aqueous solution measurement target
  • Measures 10" lenght by 1-1/4" width by 21/32" height
Salt Measurement Measurement Method: Electric Conductivity Measurement System
Measurement range: 0.001% to 5.0%
Measurement Temp: 50°F to 104°F (10°C to 40°C)
Measurement Temp. Range: 32°F to 158°F (0°C to 70°C)
Temperature Measurment Measurement Range: 32°F to 212°F (0°C to 100°C)
Measurement Accuracy: ±1°C (temp. range: 0°C to 70°C) of reading
TDS Measurement Range: 0 to 999ppm (mg/L)
Measurement Accuracy: ±3% full scale @ 20°C
Excellent Temp. Range: 50°F to 86°F (10°C to 70°C)
Measurement Temp. Range: 32°F to 104°F (0°C to 40°C)
Resolution @ 20°C Salt Measurement: 0.01% to 0.1%
TDS: 1ppm (mg/L)
Power Supply LR44 or LR1154 Button Battery (x3)
Size 16.4mm x 32mm x 255mm
Standard Accessories Sensor protection cap, supporting spoon (2), NaCl standard solution (40g), manual, and batteries

Applications

  • Water: Test TDS levels to determine purity
  • Food: Test the amount of salt in food, seafood, or processed foods
  • Health: Monitor the amount of salt intake
  • Water Filtration: Test for TDS to determine performance level of filtration systems
  • Pools & Spas: Monitor TDS levels to prevent maintenance problems
  • HVAC: Test condensate water in cooling tower and humidifier reservoir applications to prevent bacterial growth
  • HVAC: Test TDS levels in make-up water to prevent scale formation, corrosion, and embrittlement
  • HVAC: Reduce water and chemical consump tion in boilers and cooling towers
  • HVAC: Determine when to perform blowdown and add make-up water
  • HVAC: Prevent contamina tion and corrosion of control valves, heat exchangers, and steam traps
  • HVAC: Verify automated TDS contollers are functioning properly
  • HVAC: Prevent low quality wet steam generation in boilers due to foaming caused by high TDS levels
  •  

Product Description

Use for salt measurement, temperature measurement and TDS. 0.001 to 5.0 percent measurement range for salt, 32 to 212 degree F measurement range for Temperature and 0 to 999ppm measurement range for TDS. 0.01 to 0.1 percent resolution at 20 degree C for salt and 1ppm for TDS. Aqueous solution measurement target. Measures 10" length by 1-1/4" width by 21/32" height. RoHS compliant