Categories
Product Details
Overview
Two-in-one device at the price of one! Irreplaceable instrument for the specialists who work with digital and analog signals
Digital storage oscilloscope + Logic analyzer. DSO: dual channels+ external trigger; bandwidth 25 MHz. Sample rate (Real time) 100 MS/s; record length 6K points on each channel; cursor and automeasurement (20 types); trigger type: edge, video, alternate; Math; FFT; peak detect and average. LA: 16 channels; max. sample rate 100 MS/s; bandwidth 33 MHz; max storage 4M/channel; 4 trigger mode. USB Flash Disk Storage. Display: 7.8 '' color LCD, STN screen, 640×480 pixels. Dimensions: 14.6in x 7.1in x 4.7in / 370mm x 180mm x 120mm. Weight: 4.9lb / 2.2 kg
Specifications:
Digital Storage Oscilloscope
Sampling
- ACQU Mode: Sample, Peak Detection, Average
- Sampling Rate: 100 MS/s
Input
- Input Coupling: DC, AC
- Input Impedance: 1MΩ± 2%, connected with 20pF± 5pF in parallel
- Probe attenuation coefficient: 1X, 10X, 100X, 1000X
- Max. Input Voltage: 300V, Peak Value
Level
- Sampling Rate Range: 10S/s - 100MS/s
- Waveform interpolation: (sinx)/x
- Record Length: 5000 sampling points per channel
- Scanning Speed Range (S/div ): 5ns/div - 5s/div, according to the stepping mode of 1-2.5-5.
- Accuracy of Sampling Rate and Delay Time: ± 100ppm (for any time interval equal to or greater than 1ms)
- Measuring Accuracy of Time Interval (ΔT) (Full Bandwidth) Single: ± (One Sampling Interval Time +100ppm × Reading +0.6ns) >Averages of 16: ± (One Sampling Interval Time +100ppm × Reading +0.4ns)
Vertical
- A/D Converter: Resolution of 8 bits, with the sampling carried out in two channels at the same time
- Sensitivity (Volt/division) Range (V/div): 5mV/div - 5V/div (at the input BNC)
- Displacement Range: ± 10div (5mV - 5V)
- Simulative Bandwidth: 25M
- Single Bandwidth: Full Bandwidth
- Low frequency respond (AC Coupling, -3dB): ≥5Hz (at BNC)
- Rising Time (Typical, at BNC ): ≤17.5ns
- DC Gain Accuracy: ± 3%
- DC Measuring Accuracy (Average for ACQU MODE): The voltage difference (ΔV) between any two points on the wave form after averaging the captured wave forms of more than 16: ± (5% Reading + 0.05 divisions)
Trigger
Trigger Type
- Edge: Rising, Falling
- Video: Line, Field, Odd Field, Even Field, NTSC, PAL/SECAM
- Alternating
- AC line: (100 - 240 VACRMS)
Trigger Sensitivity (Edge Trigger)
- DC Coupling: Channel 1 and Channel 2: 1div (DC - Full Bandwidth)
- EXT: 100mV (DC - Full Bandwidth)
- EXT/5: 500mV (DC - Full Bandwidth)
- AC Coupling: It is the same as the DC coupling in case of 50Hz or more
Trigger Level Range
- Internal: ± 6 divisions from the screen center
- EXT: ± 600mV
- EXT/5: ± 3V
Trigger Level Accuracy (Typical): It is applicable to the signal with the rising and falling time ≥ 20ns
- Inside: ± 0.3 div
- EXT: ± (40mV + 6% of Set Value)
- EXT/5: ± (200mV +6% of Set Value)
Trigger Displacement
- Preliminary Trigger: 1300 divisions
- Late Trigger: 4 divisions
Set Level to 50% (Typical)
Operation under the condition of input signal frequency ≥ 50Hz
Trigger Sensitivity (Video trigger, typical)
- Internal: Peak-to-peak value of 2 divisions
- EXT: 400mV
- EXT/5: 2V
Signal System and Line/Field Frequency (Video Trigger Type): Supporting the NTSC, PAL and SECAM broadcast system of any field frequency of line frequency.
Measurement
- Cursor Measurement: Voltage difference (ΔV) and time difference (ΔT) between cursors
- Automatic Measurement: Peak-to-Peak Value, Average, RMS, Frequency and Cycle
Probe
1X Position | 10X Position | |
---|---|---|
Bandwith | DC up to 4MHz | DC up to fullbandwidth |
Attenuation Ratio | 1: 1 | 10: 1 |
Compensation Range | 10pF - 35pF | |
Input impedance | 1MΩ± 2% | 10MΩ± 2% |
Input Electric Capacity | 85pF - 115pF | 14.5pF - 17.5pF |
Input Voltage | 150 V DC | 300 V DC |
Logic analyzer
- Sampling rate: 20 S/s - 100 MS/s Step as 1-2-5
- Input channel: 16
- Max Storage: 4M/Channel
- Measurement bandwidth: 33MHz
- Input impedance: 1MΩ±2%
- Threshold level: 0 - 4V
- Input signal range: 0 - 5V
- Trigger position setting: Pre-trigger, mid-trigger, re-trigger
- Trigger Mode: Bus trigger, state trigger, data alignment trigger, data width trigger
- Data Search: Support
- Data System: Binary system, Decimal system, Hex
- Digital Filter: 0/1/2 optional
- Setting storage: Support
- USB storage: Support
General Technical Specifications:
Display
- Display Type: 7.8" Colored LCD (Liquid Crystal Display)
- Display Resolution: 640 (Horizontal) × 480 (Vertical) Pixels
- Display Colors: 256 Colors
Output of the Probe Compensator
- Output Voltage (Typical): About 5V, with the Peak-to-Peak value equal to or greater than 1M§Ù of load
- Frequency (Typical): Square wave of 1KHz
Power
- Mains Voltage: 100 - 240 VAC RMS, 50Hz, CAT II
- Power Consumption: < 15W
- Fuse: 1A, T grade, 250V
Enviroment
- Temperature: Working temperature: 32°F - 104°F / 0 °C - 40 °C; Storage temperature: -4°F - +140°F / -20 °C - +60 °C
- Relative Humidity: ≤ 90%
- Height Operating: 3,000 m (9,842.5 ft) Non-operating: 15,000 m (49,212.5 ft)
- Cooling Method: Natural convection
Mechanical Specifications
- Dimensions: 14.6in x 7.1in x 4.7in / 370mm x 180mm x 120mm
- Weight: 4.9lb / 2.2kg
Interval Period of Adjustment:
One year is recommended for the calibration interval period
Tell a Friend
Cart Contents
Order Info
INTERNATIONAL:954-574-0345
SCHOOL PURCHASE ORDERS:
FAX: 954-574-9528
INTERNATIONAL ORDERS:
MONEY ORDER,WESTERN UNION, OR BANK WIRE
(NOT INCL. CANADA)